The burners BBG are suitable for use in industrial furnaces and firing systems in the iron and steel industries in the precious, non-ferrous and light metal sector as well as for ore dressing. In addition, they can be used in the plastics, fibre and paper industries. Burners BBG can also be used in thermal incineration installations, as well as in driers and hot-air generators.
Gas burners for open fired applications.
Diverse possible applications thanks to wide capacity range of up to 7150 kW (27 MBTU/h)

Dokument

Certifakat

> Snabblänkar

Burners for gas BBG
Annular excess air burners
Burner with integrated recuperator BICR
Burners for gas BIC
Burners for gas BICA
Burners for gas BIO
Burners for gas BIOA
Burners for gas TRIOX
Burners for gas ZIC
Burners for gas ZIO
Excess air burner BIC..L
Ionisation pilot burners ZAI
Ionisation pilot burners ZMI
Ionisation pilot burners ZSI
Pilot burner ZIO 40
Pilot burners ZKIH
Pot burner

Burners for gas BIC

BIC 65

BIC 150

^ Tillbaka till toppen

Burners with cast steel housing, connection for ceramic tube provided.

Burner size: 50 to 140,

capacity: 10 to 360 kW,

flame shape: normal flame or long, soft flame,

gas type: natural gas, town gas or LPG,

length of burner tube: depending on ceramic tube,

connection:

gas: thread,

air: thread or flange.

The following versions are available:\r\nburner with integrated ignition lance.

Dokument

Certifakat

 

Burners for gas BICA

BICA

^ Tillbaka till toppen

Burners with aluminium housing, connection for ceramic tube provided.

Burner size: 65,

capacity: 10 to 70 kW,

flame shape: normal flame or long, soft flame,

gas type: natural gas, town gas or LPG,

length of burner tube: depending on ceramic tube,

connection:

gas: thread,

air: tube connection.

Dokument

Certifakat

 

Burners for gas BIO

BIO

^ Tillbaka till toppen

Burners with cast steel housing, steel burner tube.

Burner size: 50 to 140,

capacity: 40 to 450 kW,

flame shape: normal flame, long, soft flame or short, flat flame,

gas type: natural gas, town gas or LPG,

length of burner tube:

50 to 1000 mm,

connection:

gas: thread,

air: thread or flange.

The following versions are available:

burner with integrated ignition lance.

Dokument

Certifakat

 

Burners for gas BIOA

BIOA 65

^ Tillbaka till toppen

Burners with aluminium housing, steel burner tube.

Burner size: 65,

capacity: 90 kW,

flame shape: normal flame, long, soft flame or short, flat flame,

gas type: natural gas, town gas or LPG,

length of burner tube: 50 to 1000 mm,

connection:

gas: thread,

air: tube connection.

Dokument

Certifakat

 

Burner for gas TRIOX

^ Tillbaka till toppen

The burners TriOx are suitable for use in industrial furnaces and firing systems in the iron and steel industries in the precious, non-ferrous and light metal sector.
They are ideal for heating furnaces in the steel industry, aluminium smelting furnaces and other high-temperature applications requiring ultra low NOX emissions.

Diverse possible applications thanks to wide capacity range of up to 5500 kW (21 MBTU/h)

Dokument

Certifakat

 

Burners for gas ZIC

^ Tillbaka till toppen

 

Burners with steel-plate housing, connection for ceramic tube provided.

Burner size: 165 and 200,

capacity: 630 and 1000 kW,

flame shape: normal flame or long, soft flame,

gas type: natural gas, town gas or LPG,

length of burner tube: depending on ceramic tube,

connection:

gas: thread,

air: flange.

The following versions are available:

burner with integrated ignition lance.

Dokument

Certifakat

 

Burners for gas ZIO

ZIO 165

^ Tillbaka till toppen

 

Burners with steel-plate housing, steel burner tube.

Burner size: 165 to 320,

capacity: 630 to 5000 kW,

flame shape: normal flame, long, soft flame or short, flat flame,

gas type: natural gas, town gas or LPG,

length of burner tube: 50 to 1000 mm,

connection:

gas: thread,

air: flange.

The following versions are available:

burner with integrated ignition lance.

Dokument

Certifakat

 

Burner with integrated recuperator BICR

EGH

TSC

BICR

^ Tillbaka till toppen

The burners with integrated recuperator BICR are used for direct or indirect heating of furnace systems.

Burner size: 65/50 to 100/80,

capacity: 21 to 82 kW,

gas type: natural gas or LPG.

Dokument

Certifakat

 

Ionisation pilot burners ZAI

ZAI

^ Tillbaka till toppen

 

Thermo pilot burner for safe ignition of atmospheric gas burners in conjunction with automatic burner control units IFS/IFD or PFS/PFD.

Capacity: approx. 3 kW,

gas type: natural gas or propane

Dokument

Certifakat

 

Ionisation pilot burners ZMI

ZMI

^ Tillbaka till toppen

Pilot burner with one ignition/monitoring electrode for safe ignition of gas burners in conjunction with automatic burner control units IFS/IFD or PFS/PFD, with forced air supply.

Capacity: 0.8 to 3.4 kW,

gas type: natural gas, town gas

or LPG,

length of burner tube:

150 to 1000 mm,

connection: thread.

Dokument

Certifakat

 

Ionisation pilot burner ZSI

^ Tillbaka till toppen

 

Pilot burner with ignition electrode and monitoring electrode for safe ignition of gas burners in conjunction with automatic burner control units IFS/IFD or PFS/PFD, with forced air supply.
Capacity: 20 to 60 kW,

gas type: natural gas, propane, town gas,
connection: thread.
Special feature: closed connection housing.

Dokument

Certifakat

 

Excess air burner BIC..L

 

BIC..L

^ Tillbaka till toppen

 

For all applications requiring precise temperature control and consistent product quality. The BIC..L burner is perfectly designed for use in the tunnel kilns and intermittent systems as used in the ceramics industry. A single burner type enables you to follow all the temperature profile requirements of the kiln. Thanks to the high excess air capability of up to approx. 1500% high flue gas temperatures of up to approx. 100°C can be reached in near-stoichiometric burner operation with maximum excess air. With reliable ignition over the entire burner output range this accommodates the furnace operator's wish for a simple structured gas/air control.

Burner size: 80, 100 and 140,

capacity: 75, 150 and 300 kW,

gas type: natural gas or LPG,

length of burner tube: depending on ceramic tube,

connection: thread or flange.

Dokument

Certifakat

 

Annular excess air burners

^ Tillbaka till toppen

Excess air burners with split-ring technology, burners with cast steel housing, connection for ceramic

tube provided.

Burner size: 65 and 100,

capacity: 50 to 200 kW,

flame shape: normal flame,

gas type: natural gas, town gas or LPG,

length of burner tube: depending on ceramic tube,

connection:

gas: thread,

air: thread.

The following versions are available:

burner with integrated ignition lance.

Dokument

Certifakat

 

Pot burner

^ Tillbaka till toppen

Aluminium or cast steel housing, connections for ceramic tubes provided, with separate process air connection.

Burner size: 50 to 80,

capacity: 10 to 105 kW,

flame shape: normal flame,

gas type: natural gas, town gas or LPG

length of burner tube: depending on ceramic tube,

connection: thread.

Dokument

Certifakat

 

Pilot burner ZIO 40

ZIO 40

^ Tillbaka till toppen

Pilot burner with forced air supply for safe ignition of gas burners in conjunction with automatic burner control units IFS/IFD or PFS/PFD.

Capacity: 20 kW,

gas type: natural gas, town gas or LPG,

length of burner tube: 100 to 1000 mm,

connection: thread.

Dokument

Certifakat

 

Pilot burners ZKIH

ZKIH

^ Tillbaka till toppen

Pilot burner with forced air supply for safe ignition of gas burners in conjunction with automatic burner control units IFS/IFD or PFS/PFD.

Capacity: 2 to 7 kW,

gas type: natural gas, town gas

or LPG,

length of burner tube: 150/100 to 1000/100 mm,

connection: thread.